Tankless Flow Calculator

A tankless heater makes hot water as you use it, so its size comes down to flow and temperature rise. Choose the showers and fixtures that run at the same time to see what a unit has to deliver.

Pick your place and we set the incoming water temperature from its winter weather.

Showers running at once
At the same time as the showers

What runs at the same time

A tank stores hot water. A tankless unit makes it as you go, so it is sized in gallons per minute, not gallons. Add up what realistically runs together. We use 2.5 gallons per minute for a showerhead, which is the federal limit, about 1.8 for a faucet and about 2 for a dishwasher or washer. Two showers at once already means 5.

How cold the water comes in

We set the output at 120°F, the setting the US Department of Energy recommends. Colder winters send colder water to the heater, so the calculator uses three bands. A January low of 40°F or higher assumes 65°F incoming water, 25°F to 40°F assumes 52°F, and anything under 25°F assumes 42°F, a rise of 78°F. Warren lands in the coldest band.

How the size is worked out

The heat a unit has to deliver each hour is the flow in gallons per minute, times the rise in degrees, times 500. That figure comes from the weight of a gallon of water. We round it and place it in one of our own planning bands, based on that delivered heat. Up to 90,000 BTU per hour is a small unit. Up to 150,000 is a standard whole-house unit. Up to 190,000 is a large unit. Above that, two units are linked together.

A tankless unit trades flow for rise. The same unit gives more gallons per minute at a small rise than at a big one, which is why every tankless rating is stated at a rise.

Gas and electric limits

Gas units go up to about 199,000 BTU per hour of input, and two can be linked. Electric units top out near 36 kW, about 123,000 BTU per hour, and they need a very large electrical service. The result shows how many gallons per minute each one delivers at your rise. A plumber or an electrician checks the gas line, the electrical service and the venting before any unit is chosen.

Common questions

What size tankless heater suits a family of four?

Plan for two showers running together, about 5 gallons per minute. At Warren’s 78°F rise that means roughly 195,000 BTU per hour, which is above what one large gas unit delivers, so the result falls in the linked two-unit band. Enter your own fixtures in the calculator.

Can one tankless unit run two showers in winter?

Not quite. Two showers draw about 5 gallons per minute, and a large gas unit delivers about 4.9 at a 78°F rise. Two linked units cover two showers at full flow, while a single unit suits one shower at a time.

What is temperature rise on a tankless heater?

It is the number of degrees the heater adds to the water. Water that arrives at 42°F and leaves at 120°F has a 78°F rise. Flow ratings are quoted at a stated rise, and colder incoming water lowers the gallons per minute a unit can deliver.

Can an electric tankless heater serve a whole house?

Not by itself. A 36 kW electric model, near the top of the range, gives about 3.1 gallons per minute at a 78°F rise. That serves one shower, and the house needs a very large electrical service that an electrician has to confirm.

Does a tankless water heater need a bigger gas line?

Often. A 199,000 BTU per hour unit draws several times what a tank heater does, and the existing gas line and venting may not be sized for it. A plumber checks both first.

Data: fixture flow rates from the federal showerhead limit and typical faucet and appliance flows, the 120°F setpoint recommended by the US Department of Energy, and incoming water bands set from Daymet winter data 2015 to 2024 for each place.